Wastewater Analysis Solutions
-
Capital Controls® Series 17T2000 Amperometric Titrator
10/22/2015
The Series 17T2000 Amperometric Titrator is an analytical instrument for the electrical determination of the end point of a titration for free, combined, or total chlorine residual. It can also be used to determine bromine, iodine, ozone, permanganate, and chlorine dioxide residuals.
-
Capital Controls® Series NXT3000 High Capacity Gas Feed System
10/15/2015
The Series NXT3000 High Capacity Gas Feed System is a family of vacuum-operated, solution-feed, gas dispensing components including a vacuum regulator, meter assembly and ejector to meet customer needs for feeding chlorine, sulfur dioxide, ammonia or carbon dioxide gas. The Series NXT3000 is a versatile, high quality system which operates at sonic conditions eliminating the need for differential pressure regulation across the rate control valve.
-
Capital Controls® Series 70CV2000 Chloromatic™ Gas Control Valve
10/8/2015
The Series 70CV2000 Chloromatic™ control valve is wall mounted and responds to control signals from a water flow transmitter and/or a chlorine residual analyzer controller. Valve characteristics are provided to directly accept a pacing signal proportional to flow.
-
Capital Controls® Series NXT3000 Gas Feed System
10/8/2015
The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas dispensing components including a vacuum regulator, meter assembly, and a selection of ejectors to meet customer needs for feeding chlorine, sulfur dioxide, ammonia or carbon dioxide gas. The Series NXT3000 is a versatile, high quality system which operates at sonic conditions eliminating the need for regulating differential pressure across the rate control valve. Proven design, rugged construction, and the use of the best available materials assures precise gas feeding, low maintenance and dependable operation for the life of the equipment.
-
Ammonium Analyzer Liquiline System CA80AM
9/1/2015
Liquiline System CA80AM offers high-precision ammonium measurement in all critical control points. As member of the Liquiline platform, it enables plug & play and easy upgrade to a measuring station - minimizing the installation effort. Automatic calibration and cleaning as well as the low consumption of reagents save you operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
-
Determination Of Polycyclic Aromatic Hydrocarbons In Seafood
4/20/2015
Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds found naturally in the environment. PAHs are monitored by the US Environmental Protection Agency due to their carcinogenic characteristics.
-
Determination Of Hexanal In Foods Utilizing Dynamic Headspace
4/9/2015
Hexanal is one of many well-documented aromatic components that contribute to flavor and aroma in common consumer food products containing omega-6 fatty acids. Hexanal content is also used to measure the oxidative status of foods rich in omega-6 fatty acids.
-
Validation Of Environmental Water Methods On One System
4/6/2015
Water quality laboratories across the nation are faced with both a rising level of water quality awareness amongst the general public, as well as rising costs in water quality monitoring. As a result, laboratories are looking for more efficient ways to provide higher quality monitoring.
-
Analyzing Total Organic Carbon In Sea Water
4/2/2015
The analysis of Total Organic Carbon (TOC) in seawater can be both challenging and expensive. The concentration of organic carbon in seawater is of considerable interest. The effect this matrix can have on TOC analyzers can lead to rapid consumable turnover, costly maintenance and repairs.
-
CNSolution™ 9310 On-Line Cyanide
3/20/2015
OI Analytical’s CNSolution™ 9310 On-line Cyanide Analyzer is designed to measure available cyanide in precious metal leaching solutions by USEPA Method OIAA-1677 and ASTM D 6888-09. Unlike traditional techniques, the gas-diffusion amperometry technique used in these methods is free of interferences from copper and metallic sulfides. The 9310 On-line Cyanide Analyzer displays results in real-time and has a single piece zero-maintenance reference electrode, which simplifies instrument maintenance.